Vaillant eBUS — vaillant_ebus setup guide

Customer-facing instructions for adding a Vaillant gas boiler or heat pump to your Otonomo install. One driver covers both via two config axes:

Axis Values Picks what
device_class gas_boiler / heat_pump Which message dictionary + canonical metric namespace
mode active / passive Transport — active via local ebusd master, passive via eBUS Adapter Shield TCP tap (read-only)

Tested matrix:

Combination Tested device Status
gas_boiler + active ecoTEC plus VC 376/5-5 + ebusd 23.x ✅ stable (home box)
heat_pump + passive flexoTHERM exclusive + sensoCOMFORT VRC 720 + eBUS Adapter Shield v3 ✅ live (prospect box)
heat_pump + active Decoder ready; not yet validated on a live install ⏳ beta
gas_boiler + passive Decoder ready; not yet validated on a live install ⏳ beta

Which mode am I?

Pick the section below that matches your install.


Heat pump (passive mode) — fast path

If you have a Vaillant heat pump (flexoTHERM, aroTHERM, aroSTOR or similar) and the installer's controller (sensoCOMFORT, multiMATIC, VRC 700) is still running it, use this path. Read-only by design — we observe the bus, the installer's controller stays in charge of all control decisions.

Hardware

  1. eBUS Adapter Shield from adapter.ebusd.eu (~€87). It's a small board with WiFi/Ethernet that taps the eBUS pair and exposes the byte stream over TCP :9999 in the enhanced protocol. Plug it into mains or PoE; connect the eBUS pair from the heat-pump's eBUS terminals (polarity-insensitive).
  2. No serial cable, no ebusd install, no software on the heat-pump side. The Shield is a passive tap when no host issues commands.
  3. Note the adapter's LAN IP (DHCP-assigned; the Shield's web UI on port 80 shows it).

Configuring the driver

Add this block to your site manifest (/etc/otonomo/site_manifest.yaml):

- instance: vaillant_hp
  driver: vaillant_ebus
  version: ">=0.2.0,<0.3.0"
  config:
    device_class: heat_pump
    mode: passive
    adapter_host: 192.168.x.y   # Shield IP on your LAN
    adapter_port: 9999          # default; rarely overridden
    passive_window_s: 8.0       # capture window per poll

Restart the SDK publisher; within ~60 s the cloud dashboard's heat-pump tab populates.

What you get (heat pump, passive)

Metric Source When it lands
Flow / return / Δ-T B511 Status01 Every poll (live)
DHW tank top temperature B511 Status01 Every poll (live)
Source temperature (brine / air inlet) B511 Status01 Every poll (live)
HC pump state B511 Status01 Every poll (live)
Operating state (ready / heating / cooling / heating_water / error) B511 ID=07 When controller polls it
Controller intent — plain-English summary of the most recent SetMode write B510 passive observation Every poll once the controller writes (sub-minute)
appears_parked flag (HC + DHW load both disabled) derived from SetMode Every poll
HMU clock (ISO) B504 / B516 broadcasts Every 5–30 min
Outdoor air temperature (broadcast) B516 broadcast Every 10–30 min
Live electrical input / thermal output / compressor modulation B51A Only on controllers that poll it
Compressor on / demand B509 ID=1D / 0x54 Controller-poll-dependent
Backup heater on B509 ID=5F Controller-poll-dependent (CRITICAL — backup heater = peak-hour budget killer)
HC water pressure B509 ID=12 Controller-poll-dependent
eBUS bus health (telegrams/min, CRC error %) Self-measured Every poll

All values land in fleet-db's hp_local_* columns and render automatically on /pro/heat_pump.

What you can NOT do (today)


Gas boiler (active mode) — the original path

If you have a Vaillant gas boiler AND you've removed the installer's thermostat (so we become the room thermostat), use this path.

Prerequisites

  1. A Vaillant boiler with an eBUS port. This is almost every Vaillant gas boiler made since ~2010. Look for two unmarked screw terminals on the boiler's electronics board, sometimes labelled + / - or 1 / 2. Consult your installation manual.
  2. A USB-to-eBUS adapter. The most popular options:
  3. eBUS Coupler II (eservice-online.de, ~€80)
  4. DIY Adapter (instructables/eBus open-hardware designs, ~€20)
  5. vbus-USB (Resol-style) The Otonomo agent talks to whichever via ebusd, so any ebusd-compatible adapter works.
  6. ebusd running on the same machine as the Otonomo agent. Install with sudo apt-get install ebusd (Debian/Ubuntu) or build from source. Default config exposes a TCP API on :8888 which is what our driver connects to.

Wiring

  1. Power off the boiler at the breaker.
  2. Locate the eBUS terminals on the boiler's PCB. Polarity DOES NOT matter — eBUS is differential.
  3. Connect two wires from those terminals to the adapter's eBUS pins. Total cable length up to ~100 m, any gauge ≥ 0.5 mm² works.
  4. Plug the adapter into a USB port on your Otonomo box.
  5. Power the boiler back on.

Within 30 seconds, ebusd should detect the boiler and start polling. Verify with:

ebusctl find
# Should list: bai (your boiler), broadcast, and possibly others
ebusctl read -c bai FlowTemp
# Should return the current flow temperature in °C

Configuring the driver in Otonomo

  1. Open your local UI at http://<your-box-ip>:8080/drivers.
  2. Find vaillant_ebus under "Gas Boiler" and click Install. Otonomo pip-installs the driver into the venv (~5 s).
  3. Once installed, click Add instance. Fill in:
Field Value Why
Instance ID vaillant_ebus.boiler Unique on this box
ebusd_host 127.0.0.1 ebusd runs on the same machine
ebusd_port 8888 ebusd default
circuit bai Vaillant boiler-automation interface; most installs
timeout_s 3.0 Vaillant responds within 1 s typically
  1. Click Create instance.

Within 30 seconds, your local dashboard's Heating page lights up: DHW temp, flow/return, modulation, burner state.


Verifying it's working

In the local UI:

In the cloud dashboard:

On the command line (advanced):

mosquitto_sub -h <box-ip> -t 'hems/+/telemetry/vaillant_ebus.boiler' -v

You should see JSON messages every ~30 s.


Common pitfalls

"ERR: not authorized" reading some registers

Some Vaillant fields are gated by ebusd's local ACL (heat curve parameters, d.xx installer codes). Fix by starting ebusd with --accesslevel=*:

sudo systemctl edit ebusd
# Add:
[Service]
Environment="EBUSD_OPTS=--accesslevel=*"

sudo systemctl restart ebusd

This is safe — ebusd's ACL is local-only; nothing on the bus can abuse it.

"Hot water tank: 116.06 °C"

The Vaillant firmware returns 0x0741 = 116.06 °C when the DHW sensor isn't installed or is invalid. The Otonomo driver filters this magic value out automatically. If you still see it on the dashboard, either:

Boiler "forgets" DHW target shortly after Otonomo writes it

This is the vSMART/VR940f setback fight — a stock Vaillant thermostat re-broadcasts the previous target every few minutes, overwriting Otonomo's. Solutions in order of preference:

  1. Remove the vSMART if you don't use it. Otonomo replaces its functionality (room temp via Shelly, weather-compensated curve, etc.) and the boiler runs fine without it.
  2. Disconnect the vSMART's eBUS leads and leave the controller itself in place for warranty purposes.
  3. Set a "permanent override" on the vSMART — most models allow pinning a target temp indefinitely. Then Otonomo and the vSMART target the same value; no fight.

Flow temp clipped at 75 °C

The boiler's d.71 parameter sets a hard flow-temp ceiling. Default on most installs is 75 °C (raised from the factory 55 °C for cold- morning warmup performance). The Otonomo driver refuses to write above this ceiling — that's a feature, not a bug. To raise it:

  1. Enter installer mode on the boiler control panel (long-press the wrench icon).
  2. Find parameter d.71 and raise to your desired ceiling (max usually 85 °C).
  3. Exit installer mode.

Otonomo re-reads the ceiling on the next poll and starts allowing writes up to the new value.


What Otonomo will do with this driver

In observe mode (free trial): - Reads DHW temp, flow, return, outdoor, modulation, burner state every 30 s - Sends them to the cloud for visualization + the optimization shadow run

In active mode (€3/mo, opt-in per capability): - Hot water (DHW) capability: schedules DHW heating cycles for off-peak hours when affordable + when there's PV surplus. Pre-charges the tank before predicted high-price evenings. - Heating setpoints capability: weather-compensated flow-temp control. Falls back to the boiler's built-in curve if the cloud is unreachable (cloud-watchdog safe mode).

You can enable / disable each capability independently at https://app.otonomo.be/account/control.


References

Otonomo's vaillant_ebus is an independent interoperability tool. Not affiliated with Vaillant Group.